Optical Network Training

FTTx training written by someone who built the hardware.

Nearly twenty years in optical infrastructure and equipment development, and field training delivered in nine countries. These lessons cover what actually decides whether a link comes up: network structure, split loss, power budget, and fault localisation.

20 yrs

Fiber infrastructure and hardware development

9

Countries where training was delivered on site

20+

Hardware products developed and commercialised

17

Core patents

Who it is for

Written for the person who has to decide on site

Engineers new to fiber

You can follow the procedure, but nobody explained why the numbers are what they are. This starts at the vocabulary and the signal path.

Teams inheriting a network

You maintain plant somebody else designed. The lessons focus on reading drawings, budgeting loss, and locating faults.

Operators training in-house

Written to be handed to a new hire directly. Each lesson ends with the decisions that matter on site, not a vendor feature list.

Curriculum

Optical Network Training

From FTTx network architecture to field measurement and fault finding. A practical track built so that engineers new to the equipment can understand the principles and make their own judgement calls on site.

  1. Lesson 1

    Reading an FTTx Network in One Picture

    From the central office to the subscriber premises — the full path an optical signal travels, and what each point on it actually does.

    12 min
  2. Lesson 2

    PON and Optical Splitters — How 32 Homes Share One Fiber

    Why we do not run a dedicated fiber to every subscriber, how a passive optical network keeps traffic from colliding, and what the split ratio means in the field.

    14 min
  3. Lesson 3

    Optical Power Budget — Where a Link Lives or Dies

    The difference between dB and dBm, how to add up real link loss, and which margins you have to reserve so a design survives contact with the field.

    15 min
  4. Lesson 4

    Finding Faults with an OTDR — How to Read the Trace

    Telling splices, connectors and breaks apart on an OTDR trace, and the measurement settings that quietly change what you see.

    16 min
  5. Lesson 5

    Single-mode or Multimode — Choosing the Right Fiber

    Why access networks are almost always single-mode, what actually differs between the two, and the mistakes that happen when the wrong fiber ends up on a reel.

    10 min
  6. Lesson 6

    Fusion Splicing — What Actually Makes a Good Splice

    The five steps of a splice, what the splicer's loss estimate does and does not tell you, and why most bad splices fail before the arc ever fires.

    12 min
  7. Lesson 7

    Connectors and End-face Contamination — The Number One Field Fault

    Connector types you will meet, why polish grade matters for PON, and the inspect-clean-inspect habit that prevents most of the faults you will be called out for.

    11 min
  8. Lesson 8

    Bend Radius, Slack and Enclosure Discipline

    Why light leaks out of a bend, how much slack to leave and where, and the enclosure habits that decide whether the next engineer can work on your plant.

    11 min
  9. Lesson 9

    Aerial, Duct and Direct-buried — Route Types and How Each One Fails

    The three ways cable gets from A to B, what damages each of them, and how route choice quietly determines your maintenance workload for the next decade.

    12 min
  10. Lesson 10

    Insertion Loss Testing — The Measurement That Actually Decides Acceptance

    Power meter and light source, reference methods, and why the number you get depends entirely on how you set the reference.

    12 min
  11. Lesson 11

    Reading an OTDR Event Table Without Trusting It Blindly

    The automated event table is a starting point, not an answer. How to verify each event with markers, and the artefacts that fool the software.

    13 min
  12. Lesson 12

    Acceptance Testing — What to Record and Why It Matters Later

    Handover is the one moment when measuring everything is cheap. What belongs in the acceptance pack, and the omissions that cost years later.

    12 min
  13. Lesson 13

    The Visual Fault Locator — When Red Light Beats an OTDR

    A cheap red laser solves a class of problems the OTDR cannot touch. What it finds, what it cannot, and how to use it without hurting anyone.

    9 min
  14. Lesson 14

    Test Documentation That Is Still Useful in Year Three

    Most fiber records fail not because data was missing but because nobody could find or interpret it. What makes a record survive staff turnover.

    10 min
  15. Lesson 15

    A Triage Order for Fiber Faults

    Most outages are resolved by the first two steps. A fixed sequence that stops engineers from opening enclosures on a hunch.

    11 min
  16. Lesson 16

    Intermittent Faults — Temperature, Water and Movement

    The faults that pass every test you run. How to catch a problem that only appears at 4 a.m. in February.

    12 min
  17. Lesson 17

    The ONU Will Not Register — Working Through the Layers

    A new install that will not come up is usually not a fiber problem. Separating optical faults from provisioning faults, in order.

    11 min
  18. Lesson 18

    Rogue ONU — When One Unit Breaks the Whole PON

    A single misbehaving ONU can take down every subscriber on the port. Why the shared upstream makes this possible, and how to find the culprit.

    12 min
  19. Lesson 19

    Emergency Restoration — Getting Service Back, Then Doing It Properly

    A cut cable at night is a different job from a planned splice. What to do first, what to defer, and how to make sure the temporary repair does not become permanent by accident.

    12 min
  20. Lesson 20

    GPON, XGS-PON and the Wavelength Plan

    How multiple PON generations share one fiber, which wavelengths belong to which service, and why the plan constrains everything you can do later.

    12 min
  21. Lesson 21

    Coexistence — Running a New PON Over Existing Plant

    Upgrading without a forklift replacement. How coexistence elements work, what they cost you in budget, and the migration sequence that avoids outages.

    12 min
  22. Lesson 22

    Capacity Planning — Split Ratio as a Business Decision

    How many subscribers should share a port. Balancing loss budget, bandwidth per subscriber and construction cost, and why the answer changes over time.

    11 min
  23. Lesson 23

    In-building Distribution — Where Most Installation Time Goes

    Getting fiber from the building entry to the apartment. Riser design, bend-insensitive cable, and why the last thirty metres cost more than the last three kilometres.

    11 min
  24. Lesson 24

    What Changes as PON Rates Keep Rising

    50G PON and beyond. Which field practices matter more at higher rates, which plant decisions become irreversible, and what to do now.

    11 min
  25. Lesson 25

    Closure Cable Preparation and Tray Securing

    Cable preparation length for a splice closure comes from the manufacturer's manual. How to read sheath removal, tube securing, tray-cover pinching and re-entry checks as one sequence.

    10 min
  26. Lesson 26

    Fiber Inspection Evidence Handover

    A practical handover method linking mating-face images, inspection limits, identifiers and optical test records, with FI-3000 examples from its 2019 manual.

    10 min
  27. Lesson 27

    Dome Closure Seal Check and Leak Response

    How to pressurize a dome splice closure right after assembly and check its seals. Using Panduit installation instructions FS152 as the example: cap tightening, gasket seating, soapy-water check and leak-location actions.

    10 min
  28. Lesson 28

    OTDR Far-End Connector Loss Assessment

    A ten-minute lesson on receive fibers, pulse width, recovered backscatter and reporting boundaries for defensible OTDR far-end connector results.

    10 min
  29. Lesson 29

    Splice Protector and Tray Compatibility Checks

    A ten-minute lesson on matching tray kits, splice modules and protector part numbers, separating splice counts from fiber counts, and holding decisions when documents conflict.

    10 min
  30. Lesson 30

    Choosing Fiber for the Link You Need

    Part 1: distinguish OS/OM from ITU fibre categories, read application-specific reach tables, and specify optics, loss, connectors and cable construction.

    25 min
  31. Lesson 31

    How 5G and FTTH Shape Fiber Demand

    Part 2: connect broadband, 5G transport and AI data-centre demand to cable specifications, read market forecasts critically, and practise procurement and acceptance decisions.

    25 min
  32. Lesson 32

    How RF Signals Travel over Optical Fiber

    An instructor-led RFoF lecture covering optical conversion, analog and digital transport, link performance, fiber-plant requirements and measurement evidence.

    60-minute lecture

FAQ

On-site training questions

What does the FTTx field training cover?
It is built on the 32-lesson FTTx curriculum on this page: network structure, split loss, optical power budget, enclosure work and fault localisation — the decisions that decide whether a link comes up on site.
How are duration, cost, group size and completion arranged?
They are set after a short consultation, based on who is being trained, how many people, the plant you operate and the site conditions. Include your team size and the tasks your team keeps getting stuck on when you enquire.
Can the training follow our own equipment?
Yes. Sessions can be built around the plant you actually operate: your split ratios, your enclosures and your measurement records.
Who teaches it?
Reedo (Jongsun Park). Nearly twenty years in optical infrastructure and FTTx equipment development, with field training delivered in nine countries: Vietnam, Thailand, New Zealand, France, Qatar, Lebanon, China, Indonesia and Oman.
Which languages and formats?
Korean or English. Based in Korea and available remotely, including Zoom or Google Meet; on-site delivery is discussed case by case.
How do I enquire?
Email dms@dmssolution.co.kr. Replies usually arrive within one to two business days.

On-site training

Need this delivered to your field team instead?

Sessions can be built around the plant you actually operate: your split ratios, your enclosures, your measurement records. Tell me what your team keeps getting stuck on.

Get in touch